LQ-TAPA Tert-amyl peroxyacetate 690-83-5

Item Content
Product Name Initiator LQ-TAPA
Chemical Name Tert-amyl peroxyacetate
Molecular Formula C₇H₁₄O₃
Molecular Weight 146.20
Theoretical Active Oxygen Content 10.94%
CAS No. 690-83-5
UN No. 3107

Properties

Property Description
Appearance Colorless, transparent liquid
Solubility Insoluble in water, soluble in most organic solvents
Density (20°C) 0.923 g/cm³
Refractive Index (20°C) 1.035
Decomposition Temperature 159°C
Major Decomposition Products Tert-butanol, acetic acid, di-tert-butyl ether, methane, ethane

Safety Indicators

Half-Life Temperature
0.1 hour 134°C
1 hour 114°C
10 hours 96°C
Thermal Stability Data Temperature
Self-accelerating Decomposition Temperature (SADT) 60°C
Critical Temperature (Tem) --
Control Temperature (Tc) --
Storage Temperature (Tsmax) --/30°C
Activation Energy (E) 152.16 KJ/mol

Applications

Application Description
Polymerization Initiator (LDPE) Excellent low-temperature initiator for LDPE, especially in tubular processes. Can be combined with other initiators like LQ-TBPV, LQ-TBPEH, or LQ-TBPB for enhanced polymerization.
Curing Agent for Thermoset Resins Used as a high-temperature curing agent for unsaturated polyesters.
Polymerization Initiator (Styrene and Acrylates) Initiator for the polymerization of styrene or styrene copolymers, as well as methyl methacrylate and vinyl acetate.

Packaging and Transport

Packaging Description
Standard Packaging Typically packaged in 20 kg polyethylene containers. Custom packaging available upon request.
Transport Follows transportation regulations for organic peroxides (Class 5.2, UN 3107).

Storage Instructions

Precaution Description
Storage Conditions Store in a cool, ventilated area with a maximum temperature of 30°C. Keep away from acids, reducing agents, flammable materials, and other reactive substances.
Storage Facilities Ensure proper ventilation, and use explosion-proof lighting and switches outdoors.
Handling Precautions Handle carefully to avoid container damage. Prevent impact and vibration. Personal protective equipment should be used during repacking and handling.

Fire Protection

Precaution Description
Small Fire Handling For small fires, use foam or dry powder extinguishers immediately, followed by large amounts of water to prevent re-ignition.
Large Fire Handling In case of large fires, evacuate to a safe distance and use water hoses for firefighting. Notify fire services for assistance.

Address

Lanzhou City, Gansu Province, China

Call Us

+86 13775225407

Email Us

info@lzaux.com

en_USEnglish